MC102-Micro-Pump-VMECA

MC102

Micro Vacuum Pump

  • Max Vacuum Level: -83 kPa
  • Open Vacuum Flow: 16.5 Nl/min
  • Air Consumption: 10.6 Nl/min @ 2.6 bar

SKU: MC102

Category: Micro Pump / Vacuum Generators

The MC100 series is a micro vacuum pump with a built-in VMECA Micro-Cartridge that provides stable vacuum levels and flow. This pump is designed for stackable and individual vacuum generators. Especially, all the components needed for a vacuum system are integrated so there is no need for any additional vacuum components.

High operational reliability despite fluctuating or low compressed-air pressure

Low energy consumption

Compact size and light weight

Push-in type direct hose fitting

MC102 Series

1. Basic Model

Symbol Description
MC102 Micro pump, 2-stage cartridge, Plug

2. Body Type

Symbol Description
S Single unit
M2 2-Stacked vacuum pumps
M4 4-Stacked vacuum pumps
M6 6-Stacked vacuum pumps
M8 8-Stacked vacuum pumps
M10 10-Stacked vacuum pumps

3. Air Control Value

Symbol Description
Blank No air control valve – Only for single unit /option 2
A Normal closed (NC) air & vacuum release control valves
B Normal closed (NC) air control valve

4. Vacuum Switch

Symbol Description
Blank No vacuum switch
C LED Vacuum Switch, No analog supply, M8-3-pins connector, NPN
PC LED vacuum switch, No analog supply, M8-3-pins connector, PNP
G LED vacuum switch, No analog supply, 3 m lead wire, NPN
PG LED vacuum switch, No analog supply, 3 m lead wire, PNP
V11N Digital vacuum switch, Analog supply, 30 cm lead wire, NPN
V11P Digital vacuum switch, Analog supply, 30 cm lead wire, PNP

5. Sealing Materail

Symbol Description
Blank NBR sealing material
V Viton sealing material
E EPDM sealing material

1. General Specifications

Max Vacuum Level -83 kPa
Open Vacuum Flow 16.5 Nl/min
Feed Pressure 1.2 ~ 2.6 bar (Max 7 bar)
Temperature -20 ~ 80 ℃
Noise Level 50 ~ 60 dB
Weight – Basic Pump 14.1 g / Single unit

2. Vacuum Flow

MC102 Series

Max Vacuum Level Feed Pressure Vacuum Flow (Nl/min) at different vacuum level (-kPa)
-kPa bar 0 10 20 30 40 50 60 70 80 90
80 2.6 16.5 11.9 5.1 2.3 1.4 1.3 0.9 0.3 0.12
83 2.2 14.2 9.4 3.3 2.2 2 1.4 0.8 0.4 0.18
50 1.2 11.5 6.3 2.2 1.6 0.7

3. Evacuate Time

MC102 Series

Feed Pressure Air Consumption Evacation time in seconds per literto reach different vacuum level (-kPa)
bar Nl/min 10 20 30 40 50 60 70 80 90
2.6 10.6 0.34 1.6 3.9 7 10.4 17.5 30.9 61.4
2.2 9.6 0.4 1.48 4.3 6.9 9.1 15.3 27.4 50.2
1.2 6.8 0.68 3 6.1 11.8 27.2

MC102: Basic Pump

Unit: mm

 MC102 Series

No Description
1 Compressed-Air Port, ∅4
2 Vacuum Port, ∅4
3 Exhaust Port

MC102: With Optional Parts, LED Vacuum Switch

Unit: mm

MC102 Series

No Description
1 Compressed-Air Port, ∅4
2 Vacuum Port, ∅4
3 Exhaust Port
4 LED Vacuum Switch

MC102: With Optional Parts, Digital Vacuum Switch

Unit: mm

 MC102 Series

No Description
1 Compressed-Air Port, ∅4
2 Vacuum Port, ∅4
3 Exhaust Port
4 Digital Vacuum Switch

Vacuum Pumps & Spare Parts

Part Number Description
VC102 Micro vacuum cartridge, 2-stage
MC102-S Micro pump, 2-stage cartridge, Plug, Single unit
VCP-M7 Holding plug for MC102

Catalog Files

Catalog
MC102 PDF Icon

Related Products

VMECA-Email_icon